PRODUCTS

Membrane Product Customisation

ULP (Ultra Low Pressure) Membranes

Brief Introduction
The ULP/XULP series of membrane elements (TFC – Thin Film Composite) are made of Polyamide composite membrane materials, which can achieve the desired permeate water and high desalination rate under ultra-low/extreme-low pressure operation conditions. The operating pressure is 2/3 of the conventional composite membrane pressure, and the desalination rate can reach 99.3%. It can improve economic benefits, including reducing the investment cost of related pumps, pipelines, containers, and other equipment, as well as the operation cost of the whole reverse osmosis system.

ULP/XULP series of membrane elements is suitable for desalination treatment of surface water, groundwater, tap water, and municipal water with salt content less than 2000 ppm. It is mainly used in various fields of industry, such as pure water, boiler recharge water, food processing, and pharmaceutical manufacturing.

Scope of Application

It is mainly used in various fields of industry, such as pure water, boiler recharge water, food processing and pharmaceutical manufacturing.

Brochure Download →

Product Details

  • ULP/XULP series of membrane elements performance
ModelMembrane  ft2 (m2)Average Permeate GPD(m3/d)Stable Rejection %Min. Rejection%
RM-XULP-402142(3.9)950(3.6)99.097.5
RM-XULP-404085(7.9)2000(7.5)99.097.5
RM-ULP-252116(1.5)300(1.13)97.597.0
RM-ULP-254033(3.0)750(2.83)99.097.0
RM-ULP-402142(3.9)950(3.6)99.098.0
RM-ULPD-404085(7.9)2300(8.7)98.598.0
RM-ULPH-404085(7.9)2000(7.6)99.098.5
RM-ULP31-404089(8.3)1900(7.2)99.599.0
RM-ULP-8040400(37)10500(39.5)99.098.5

 

  • ULP/XULP series of membrane elements Testing Conditions
Testing Pressure150 psi (1.03MPa)/100 psi (0.69MPa)
Temperature of Testing Solution25 ℃
Concentration of Testing Solution (NaCl)1500ppm
pH Value of Testing Solution7.5
Recovery Rate of Single Element15%(8040、4040、2540);8% (4021、2521)

 

  • ULP/XULP series of membrane elements Operation Limits & Conditions
Max. Working Pressure600psi(4.14MPa)Max. Feed Water SDI 155
Max. Feed Water Flow75gpm(17 m 3 /h)For 8040
16gpm(3.6 m 3 /h)For 4040、4021
6.0gpm(1.4 m 3/h)For 2521、2540
Max. Feed Water COD10ppm
Max. Feed Water BOD5ppm
Max. Feed Water TOC10ppm
Max. Feed Water Temperature45℃Residual Chlorine
Concentration of Feed Water
< 0.1ppm
Max. Feed Water TDS2000ppmpH Range of Feed Water
During Continuous
Operation
2 ~ 12
Max. Feed Water Hardness60ppmMax. Pressure Drop of Single Element15psi(0.1MPa)
For8040、4040、2540
10psi(0.07MPa)
For2521、4021
Max.Turbidity NTU1

 